Causes of Mechanical Splice Termination Failures

FTTH (fiber to the home) has become increasingly popular in optical communication industry. Fiber optic termination, as one of the topics which have never been out of fashion in this field, has naturally become a focus of FTTH network deployment, especially the indoor termination. In FTTH network, mechanical splice connectors are usually used in FTTH indoor termination with the advantages of flexibility, fast-installation and cost-effective. Currently manufactures can provide various types of mechanical splice connectors of high quality which have low insertion loss and high performance. However, no matter how excellent the mechanical splicing technology is, there are still fiber optic termination failures and bad fiber optic termination due to improper operation. To avoid it, this post is to offer the causes of mechanical splice termination failures.
The Basic of Mechanical splicing
Before finding the cause of mechanical splice failure, the basic of mechanical splicing should be introduced. To finish a mechanical splice, the buffer coatings of fiber optic should be removed mechanically with sharp blades or calibrated stripping tools. In any type of mechanical stripping, the key is to avoid nicking the fiber. Then the fibers will be cleaved. Two fiber ends are then held closely in retaining and aligning a mechanical splice connector with some index matching gel between them. The gel are used to form a continuous optical path between fibers and reduce reflecting losses.
mechanical splicing
Causes of Mechanical Splice Termination Failures
Mechanical splice connector is sensitive to many factors. There are also a large number of factors to cause failures. However, most of the factors are located at the end face of fiber optic. The following is to describe them in details.
Contamination
When facing mechanical splice failures, there would be no argument that contamination is the first thing to think about. There are many ways that contamination can be carried into the fiber termination splices. Generally, there are the following possible causes of splice contamination:
  • Using a dirty cleave tool: as the fiber should be cleave before inserted in the connector, a fiber optic cleaves would be used. If a dirty cleave is used, the contamination would be attached on the end face of the fiber optic and be embedded in the connector. Thus, do remember to clean the surfaces thoroughly with alcohol wipes;
  • Wiping the fiber after cleaving;
  • Setting the connector or fiber down on a dusty surface;
  • Heavy airborne dust environment;
  • Glass fragments from insertion broken fibers, or applying excessive force;
  • Polluted index matching gel.
comtamination
Please note that once the contamination is carried inside the mechanical splice connector, especially with the index matching gel, there would be little possibility to clean them out, which means the connector may be scrapped.
Glass Fragmentation
Improper operation like overexertion when inserting the fiber optic into the mechanical splice connector might break the fiber optic and produce glass fragmentation which will cause air gap and optical failure. Or if a broken fiber if inserted, there will also be optical failure. If the glass fragments are embedded in the connector, they cannot be cleaned out and the connector would be scrapped. Thus, be gentle and carefully when splicing the fiber ends.
glass-fragmentation
Bad Cleave
Cleaving the fiber optic is an important step during fiber optic mechanical splicing. The quality of the cleave can decide the quality of the optical splice transmission to some degree. It is not easy to inspect the cleave quality in the field. There are several possibilities there might cause the bad cleaves:
  • Dull or chipped cleave tool blade
  • The bent tongue on the cleave tool concentrated too much bend stress on the fiber
  • Bending the fiber too much or too tight of a radius
  • Applying no tension or insufficient tension to the fiber while cleaving.
bad cleave
Excessive Fiber Gap
Fiber gap is another factor that might cause the fiber optic termination failure. The fiber optic transmission is very sensitive to the gap between two fiber ends in the mechanical splice connector. Improper operations that might cause the excessive fiber gap are listed as following:
  • Cleaving the fiber without enough lengths;
  • The fiber is not fully inserted, or pulled back during termination;
  • The fiber was not held steady during termination and was pushed back into the fan-out tubing when terminating outdoor cable.
These faults can be corrected one time.
fiber gap
Excessive Cleave Angle
During fiber cleaving, cleave angle can be produced easily and is difficult to be inspected in field. These angles are typically ranging from 1 to 3 degree. Even with precision tool, there might still be cleave angle ranging from 0.5 to 1 degree. The angle is generally produced by bent tongue, fiber bending or insufficient fiber tension.
cleave-angle
However the cleave angles can be corrected by fine tuning with a VFL (visual fault locator). Rotating the fiber while using a VFL and terminate the connector at the position (as shown in the following picture).
VFL-tuning-fiber
Conclusion
Fiber optic mechanical splicing gives quick and high quality result at a low price for fiber optic termination. Choosing the right fiber optic mechanical splice connector and fiber optic cleaver of high quality is not enough. Acknowledge the possible causes to fiber optic termination failures and use the right tools with skills can reduce the risk of termination failure effectively.

Monday, October 19, 2015

G.fast Offers Fiber Speed Ethernet Over Copper

The demand for higher data rates is continuously increasing driven by the applications like Cloud Computing, Big Data and Internet of Things. Meanwhile, the strong market competition makes the network operators to improve the network architecture and deliver high speed services. Pure fiber network should be the best solution. There is no wonder that the fiber network is the trend of the future and it is gradually extended closer to users during the transition from copper-based access networks to pure fiber networks. However, it is not favorable to connect the fiber directly to the customer premises and the cost is high in some cases, like old buildings. To find the fast and cost-effective way to deliver Gigabit speed Ethernet, copper access technology is being applied in some cases. This technology is known as G.fast.
G.fast and FTTdp
G.fast, based on the latest VDSL technology including cross talk cancellation and re-transmission, is designed for use in a 'last-mile' of less than 250 meters. Combining the advantages of fiber optic access technology and copper access technology, G.fast can deliver data at fiber speed to the customers using telephone copper wires.
The problem with G.Fast is that its ultra-fast speeds only work over very short distances. To shorten the copper distance, FTTdp is usually applied with G.fast. "dp" here stands for "distribution point". This solution brings the fiber optic cable out of street cabinets and moves it closer to home via the distribution point. The following network diagram shows the difference of FTTH and FTTdp using G.fast. The blue lines represent fiber optic cable, the red ones represent copper wire.
G.fast and HTTdp
G.fast Shifts the Limits of Copper
It seems that there is no need for copper access in building a FTTx connection. But in practice, connecting the fiber directly to the customer premises causes some disadvantages which can be solved by G.fast.
There might be many difficulties when deploying fibers to the user homes, especially some existing buildings. Sometime it is even not possible to deploy fibers to the user homes. In addition, most in-house telephone installations still rely on copper cables for most existing and newly constructed buildings because fibers are expensive and difficult to handle. There is no need to deploy fiber optic cable in building and home when delivering Gigabit Ethernet with G.fast.
The fiber optic based customers premises equipment (CPE) are usually installed by technician. Compared with fiber optic connections, copper-based CPE installation is simple. Just connecting the CPE to the telephone plug with the delivered cable would finish the installation, which can be installed by customer. Thus, G.fast can save the cost for new users and makes the home installation much easier.
Optical fibers can be broken or have transmission loses when wrapped around curves and optical fibers require more protection around the cable compared to copper. What’s more, the fault location from the CPE is not easy. It would cost more to maintain the fiber connections compared with copper connections achieved by G.fast.
G.fast Paves the Way to FTTH
At first glance, G.fast is limiting the transmission from copper to fiber. Actually, G.fast accelerates the deployment of fiber optic networks. It cost a lot of time and money to process the paperwork and get permission of the subscriber before deploying the fiber optic cable. The processing is complicated. Hardware foundation is the main advantages of G.fast which eliminates the need to rewire the whole building and still allows a noteworthy uplift in access speeds. Copper is everywhere in telecommunication network. The hybrid copper/fiber approach—G.fast making full use of the telephone wires in the buildings actually makes the customers closer to optical fibers in time save and cost save manners. In this way, the transmission from copper to fiber is actually being promoted by G.fast.
Weighing time, broadband speed and cost, operators figure out that applying G.fast in FTTH is an economical and time-saving way to bring Gigabit speed Ethernet to the users. To capture market share of broadband service, some network operators are considering to use G.fast. Alcatel-Lucent and communications services company BT have already started a consumer trial of G.fast technology in Gosforth (situated in North-Eastern England), for offering ultra-broadband access to consumers.